1 800 255 4417 www.castrol.com/GPS March 2017 Services Fluid Performance Measurement Fluid performance may be measured through a variety of means, including the following: Power/torque Dynamometer and load – (Kws/Ncm) Power is a good indicator of the lubricity of the fluid, especially with aluminum machining. Typically, less power draw indicates better lubrication and cooling at the point-of-cut. Product D Product C Product B Product A 0.39 0.38 0.37 0.36 0.35 0.34 0.33 0.32 0.31 0.30 Power (Kws) 95% CI for the Mean Tapping Power - Product positioning 11/15/2016; DGP160043 sample size 18 Material - cast aluminum Tool - M8 x 1.25 Form Tap Surface finish of component Profilometer, Ra (µm) Surface finish is important for many operations and can be measured by the profilometer to compare performance amongst various fluids. Product A: Good surface finish (0.1 Ra) Product B: Poor surface finish (>1.0Ra) P 11