Issue link: http://read.dmtmag.com/i/814629
Technical Training and Reference Info Metalworking Technical Training Cutting and Grinding 1 800 255 4417 www.castrol.com/GPS March 2017 Caring for Metalworking Fluids Concentration Control One of the most important aspects of maintaining coolant systems is a regular check of the concentration. Metalworking fluids are blends of water with many chemical components, each of which can deplete naturally over time. Two of the most important elements of a metalworking fluid are the rust preventive package and the biocide, or preservative. To maintain these components at the proper concentration, coolant concentrate must be added regularly to avoid rust problems and odors and to ensure consistent fluid performance. Coolant concentrate should be added daily or whenever water is added, preferably with an automatic proportioner as shown in Figure 20 on the preceding page. Since much of the fluid loss in a system is from evaporation of the water, coolant concentrate should only be added at about 1/3 of the target concentration of the system. For example, if you have a 9% concentration target for the system, set the proportioner to make-up the system with 3% concentration. Adjust as necessary to maintain consistent target concentration over time. Concentration should be checked regularly as it is the most important characteristic in maintaining coolant control. A daily check before starting production is ideal to ensure the coolant is within specification. A handheld refractometer is the best field tool for quickly checking concentration (Figure 21), especially on fresh coolant; but, over time, dirt, hardness and oil may build up in a fluid system. These "particles" will give a falsely high reading on a refractometer. A refractometer is only completely accurate on fresh fluid charges and systems with very good filtration. For this reason, spot-checks in a laboratory using more accurate methods such as alkalinity and acid split may be necessary. To get the best results in the field, use coolant from the clean side of the system and calibrate the refractometer regularly. Incorrect coolant concentration is often to blame for many problems that arise in machining operations. If the concentration gets too high or too low, there are negative outcomes. (Shown in Figure 22.) Figure 21. Handheld refractometer for checking coolant concentration. The reading from the viewfinder is the Brix %, which must be multiplied by the coolant's refractometer factor to get the actual concentration. Proper procedure when using a refractometer: Concentration by Refractometer 1. Clean the glass with a soft, lint-free cloth. 2. Calibrate (i.e., "zero out") the refractometer using the same water source that is mixed with the coolant. Adjust to zero using the adjustment screw. 3. Check the Brix % of the coolant by applying a few drops and looking through the viewfinder towards a light source. 4. Calculate the coolant concentration using this formula: Coolant Concentration = Brix % x Refractometer Factor Note: The Refractometer Factor is different for every coolant. Check with the manufacturer for details. Consequences of Improper Concentration Control Low Concentration High Concentration • Promotes bacterial growth • Reduces rust protection • Shortens fluid life • Leads to machining problems • Reduces tool life and/or causes tool breakages • Wastes coolant • Can cause dermal irritation • Can cause staining (primarily nonferrous materials) • Creates residue buildup • Reduces cooling (smoking and burning) • Potential for foam Figure 22. Potential consequences of incorrect coolant concentration. Q19

