Issue link: http://read.dmtmag.com/i/814629
Technical Training and Reference Info Lubrication Technical Training 1 800 255 4417 www.castrol.com/GPS March 2017 Greases and Bearings Bearing Lubrication Oil mist systems are used infrequently. They use compressed air to create a fine oil mist, as opposed to air-oil systems where the oil remains in larger droplet/ liquid form. Oil is delivered as a mist through the lube lines, then condensed back to liquid form with reclassifier fittings prior to entering the bearing. A thorough understanding of how your lubrication systems operate is essential to ensure that adequate lubricant is being supplied to all lube points. It is important to note that these systems are not "automatic/set it and forget it." They require on-going maintenance and routine inspection to ensure proper operation. Oil vs. Grease Lubrication As mentioned earlier, oil is the best overall lubricant, but grease serves many important lubrication needs. Comparison of these two lubricants for bearing lubrication is shown here. Grease • Used in the majority of bearing applications • Simplifies the lube system and housing • Stays in and seals out contaminants • Over-greasing can cause high operating temperatures Oil • Used for higher speeds and higher temps (removes heat) • Used when adjacent components (e.g., gears) are oil-lubricated (splash or circulating oil system) • Small amount of oil is all that is necessary for proper lubrication (Figure 25) • Circulating oil system is preferred application method (fresh, clean, cool oil to bearings) Figure 25. Proper oil level for bearing lubrication is only about 50-100% of the height of the lowest roller. Figure 24. Air-oil lubricant delivery system. Lubricating oil Continuous flow of oil Compressed air Oil-air Central Lubrication Systems For equipment that has many lube points and/or needs frequent re-lubrication, centralized lubrication systems are often employed to reduce maintenance time and increase lubrication reliability. A variety of centralized lubrication systems are available. These systems consist of reservoirs, pumps, distribution headers, metering valves or orifices and lines to individual lube points. Examples include: • Single-Line Resistance, a.k.a. Orifice (Bijur type) • Single-Line Parallel Injector (Lincoln type) • Single-Line Series Progressive (Trabon type) • Dual-Line Parallel (Farval type) • Air-Oil • Oil Mist Note: Single-line and Dual-line systems are discussed in more detail in the Slideway section of this technical document. Air-oil systems use airflow to carry the oil to bearings or other lube points. The oil is metered precisely into compressed air, which carries the lubricant along the outside of the delivery lines (Figure 24). This provides clean, fresh oil to the bearing on a continual basis. These systems are becoming more popular on rolling mill bearings and caster bearings in steel mills. R66