Issue link: http://read.dmtmag.com/i/814629
Technical Training and Reference Info Metalworking Technical Training Cutting and Grinding 1 800 255 4417 www.castrol.com/GPS March 2017 Caring for Metalworking Fluids The basic steps for cleaning out an individual machine sump are as follows: 1. Pump out the old coolant and physically remove all chips, sludge and fungal masses present. Make any needed repairs to sump, filters, piping, nozzles, etc. 2. Charge the system to pumping capacity with a heavy duty alkaline machine cleaner (such as Castrol Techniclean MP Flex) at recommended concentration (typically 3%). 3. Circulate cleaner solution for two to four hours* to loosen dirt, debris and excess build up. 4. Pump out the cleaner fluid and physically remove any remaining fluid, sludge and dirt. 5. Charge the system to pumping capacity with a rinse solution using water and low concentration of the new coolant (typically 2-3% to prevent flash rust). 6. Rinse the system until all cleaner residue is collected. 7. Pump out the rinse solution thoroughly. 8. Fill the system 1/3 to 1/2 full with water and add the full amount of coolant concentrate needed to achieve target concentration at full capacity. — Additions of coolant concentrate should always be made at a point of agitation and, if possible, the system should be set to cycle the fluid continuously. 9. Continue to fill the system with water until the system is at full volume. 10. Confirm that target concentration has been met and adjust as needed. Note: The cleaner stage is important to ensure that all old fluid, sludge and residues are removed. The rinse step is equally important to remove the cleaner so it does not contaminate and reduce the effectiveness of the new coolant. Metal removal fluids need to be mixed a certain way for their chemical makeup to be correct. The best way to remember the proper technique is by the acronym O.I.L. = Oil In Last. Always mix oil-containing emulsions (soluble oils and semi-synthetics) in this manner. Slowly introduce the fluid concentrate into the water while mixing vigorously; or, preferably, use a proportioner, which draws the coolant concentrate into the solution as water is added to the system. Once adjusted properly, a proportioner will help maintain a more consistent concentration than separate additions of water and coolant. *Circulation time is dependent on system size and degree of dirtiness. More than 4 hours may be needed. Figure 20. Coolant proportioner for mixing coolant concentrate automatically with water additions. Image courtesy of Dosatron USA. Q18