Issue link: http://read.dmtmag.com/i/814629
Technical Training and Reference Info Metalworking Technical Training Cutting and Grinding 1 800 255 4417 www.castrol.com/GPS March 2017 Caring for Metalworking Fluids Generally speaking, coolant should have the best filtration possible while weighing the costs and overall benefits. These typically include longer tool life, extended coolant life, lower operator dermatitis, improved machining characteristics and lower lubricant leaks from abrasion. Multiple types of filtration may be used on the same system to achieve higher cleanliness levels, such as the use of magnetic filtration as a secondary filter to polish the coolant and remove very small fines. Biological Control Controlling the micro-organisms contained within the coolant is important to long-term fluid health. Bacteria and fungus feed on oil, fatty materials, corrosion inhibitors and other components of the coolant. They can lead to emulsion instability, odors, corrosion, poor tool life and reduced coolant life. "Monday morning odor" is the result of anaerobic (oxygen-hating) bacteria, which grow readily in stagnant coolant with low levels of oxygen. Bacteria flow freely and quite uniformly throughout the coolant system, multiplying at a high rate if left untreated. Fungus, which is also referred to as mold, are multicellular, filamentous organisms that tend to attach themselves as growing masses to surfaces. If they are disrupted and, as a result, break off from the body of the organism, they may continue growing independently, resulting in the propagation of new masses in other areas of the system. Typical problems resulting from a fungal outbreak include the plugging of filters and transfer lines in addition to the generation of musty, locker-room like odors. To reduce biological problems, choose a coolant with high resistance to attack; keep tramp oil out of the system; and maintain good system cleanliness. If bacteria counts increase in a high-quality coolant, often the addition of coolant concentrate will take care of the problem. In cases of poor coolant or poor resistance, biocides may be used. If coolant will remain stagnant for an extended period, circulating or aerating the coolant regularly will keep the anaerobic bacteria levels in check. Treatment of a system under fungal attack requires the physical removal of all fungal masses in addition to chemical treatment with a fungicide. General Housekeeping and Hygiene Housekeeping and personal hygiene are an important aspect of the overall operation when working with metalworking fluids. If you have any concerns, please contact your health and safety staff and refer to the fluid's SDS (Safety Data Sheet). General recommendations are listed in Figure 25. Recommendation Why this helps Keep contaminants out of the fluid (trash, cigarette butts, mop water, etc.) Keeps the fluid clean and functioning properly and extends its life. Minimize contact with coolant (use gloves or barrier creams if you must come into contact) Some coolants can "defat" or remove oil from your skin, leading to dryness, cracked skin or irritation Wash hands regularly Wash prior to using the restroom, eating, drinking or touching your face and eyes to keep coolant away from sensitive areas. Change clothes daily The fluid can soak into your clothes and become concentrated in that area. Do not use additives in the coolant without approval Many additives are sensitizers and some chemicals should never be used (such as bleach and sani-tabs). Do not eat or drink on the plant floor This adds to contaminants in the fluid and also the fluid can splash onto either the food or drink. Use proper PPE Helps to protect your skin, ears and eyes. Figure 25. Recommendations for proper housekeeping and personal hygiene when working with coolants. Q22

