Castrol GPS

GUIDE TO INDUSTRIAL PRODUCTS AND SERVICES

Issue link: http://read.dmtmag.com/i/814629

Contents of this Issue

Navigation

Page 307 of 385

Technical Training and Reference Info Lubrication Technical Training 1 800 255 4417 www.castrol.com/GPS March 2017 Fundamentals of Lubrication Figure 38. Two samples run in a foam test. Sample on the left had no anti-foam additive, while the sample on the right did. Lubricant Characteristics and Additives Foam Control Air will be forced into an oil naturally as it is agitated and circulated within a system. Thus, the oil should be formulated properly to prevent excess foam from creating problems (Figure 38). When a lubricant foams, the ability to lubricate and transfer heat is reduced. Foam can be a housekeeping issue and cause excess oil usage, increased oxidation, pump cavitation and slow or erratic system response. Foam is most commonly tested using the ASTM D-892 method, as follows: • Oil sample of 200 mL is added to a graduated cylinder • A diffuser stone is immersed in the oil • Air is pumped through the stone continuously for 5 minutes • The amount of foam (in mL) after the 5 minute blowing period is recorded — This is referred to as the foaming "tendency" • The amount of foam (in mL) remaining after a 10 minute settling time is recorded — This is referred to as the foaming "stability" • Three sequences are run: — Sequence I at 75˚F — Sequence II at 200˚F — Sequence III at 75˚F (repeat of Sequence I) Anti-foam additives are surface-active, thus preventing air from being trapped within the oil structure. But even with proper formulation, a lubricant can foam due to excess small fines or system issues that force too much air into the oil, as shown in Figure 39. Figure 39. Causes of cavitation and aeration in hydraulic systems. • Blocked or restricted pump inlet – Strainer clogged – Collapsed inlet hose – Damaged (crimped) inlet line – Inlet line too small – Too many bends in inlet line • High oil viscosity (low temp) • Blocked reservoir breather • Pump too high or too far from reservoir • Excessive pump RPM • Water in the oil Cavitation • Low fluid level in reservoir • Defective pump shaft seal • Return line above fluid level in reservoir • Poor baffling in reservoir • Undersized reservoir • Loose fitting on pump inlet line • Defective seal on pump inlet line • Porous hose on pump inlet line Aeration R21

Articles in this issue

Links on this page

view archives of Castrol GPS - GUIDE TO INDUSTRIAL PRODUCTS AND SERVICES