Issue link: http://read.dmtmag.com/i/814629
Technical Training and Reference Info Lubrication Technical Training 1 800 255 4417 www.castrol.com/GPS March 2017 Greases and Bearings Figure 9. Water Spray-Off Test, ASTM D 4049. Courtesy of "The Lubrication Engineers Manual," AIST. The dropping point varies primarily by the type of thickener used, but also is affected by the base oil and additives. Complex greases (lithium complex, calcium complex, etc.) often achieve 500˚F dropping points, while their non-complex versions are generally in the range of 275-350˚F dropping point. Non-soap greases such as polyurea and clay are typically 450˚F or higher. Our rule of thumb indicates that the upper temperature range for a grease should be well below the dropping point to ensure oil separation is avoided. Many other factors affect the determination of a grease's upper limit, including base oil type, additives, oxidation stability, overall grease performance and re-grease frequency. For example: if the operating temperature is very close to the dropping point of the grease, problems can be avoided by replenishing the grease more frequently. Also, care should be taken so that small grease lines are not exposed to high temperatures, because the grease can separate and block the line. Grease Characteristics In the lab, grease is loaded into a small cup with a hole in the bottom and heated up (Figure 8). The temperature at which the first drop falls from the grease cup is considered the dropping point. Figure 8. Dropping point of a grease. 300˚F 400˚F 500˚F No Drip First Drop (Dropping Pt) No Drip Rule of Thumb The highest usefule temperature of a grease is 100° F to 125° F below its dropping point Water Resistance Water resistance testing determines how well a grease will stay in place in a wet environment. This is important in applications where water spray and/or wash are unavoidable due to poor sealing or by the general nature of the environment. The two most common lab tests are: Water Washout (ASTM D 1264): Determines the washout resistance of a grease from a bearing • Grease is packed into a ball bearing • Water is sprayed at low pressure onto the rotating bearing at 5 milliliters per second (mL/s) • This test aims to simulate real world conditions Water Spray-Off (ASTM D 4049) (Figure 9): Evaluates the spray-off resistance of grease on a metal panel • Grease is spread onto the metal panel • Water is sprayed at high velocity onto the panel for five minutes • This test aims to provide data under the most aggressive spray conditions WATER AT 100° F FILM OF GREASE 12" R58