Compressors
Compressor Cleaning and Oil Conversion
Compressor Cleaning Procedure with Detergent
Cleaner (such as Castrol Techniclean SC 320)
The following changeover procedure is recommended
for compressors that contain a minimal to moderate
level of buildup:
1. Operate the unit for at least one hour to get the
system to normal operating temperature.
2. Sample the compressor oil to determine amount of
contaminants.
3. Based on the results obtained from laboratory test
report, charge the system with the recommended
3-5% by volume of Techniclean SC 320.
4. System should be run for a minimum of 36 to
72 hours before oil is drained and changed. Note:
No advantages may be obtained by continuing use
for more than 72 hours.
5. Drain oil and refill system with the appropriate
compressor oil.*
6. Sample oil after 36 to 48 hours. This sample will serve
as the baseline and will help determine the success
level of the changeover.
*Note: If significant volume of contaminated oil remains
in the system after draining, a flushing step to eliminate
the remaining amount is recommended.
R85