Castrol GPS

GUIDE TO INDUSTRIAL PRODUCTS AND SERVICES

Issue link: http://read.dmtmag.com/i/814629

Contents of this Issue

Navigation

Page 272 of 385

Technical Training and Reference Info Metalworking Technical Training Cleaners 1 800 255 4417 www.castrol.com/GPS March 2017 Control and Care of Cleaners Laboratory Titration • Measurement of the alkalinity of cleaners in lab bench test • Sample is titrated with acid until reaching a pH endpoint or an indicator changes color • The amount of acid used in the titration determines the concentration via factor conversion Figure 16. Lab set up for alkalinity titration. Additional Analysis for Contamination and Depletion Other analyses can be performed on alkaline cleaner samples to determine contamination levels and component depletion. These tests include checks for hardness, tramp oil, chlorides, dirt, bacteria, fungus, ferrous corrosion inhibitors and bi-metal corrosion inhibitors. Conductivity analysis can be made to determine the potential for galvanic corrosion. Control Plans To ensure consistent and effective performance of alkaline or emulsion cleaners, control plans are recommended. The control plan is used for guidance when operating parameters fall out of the limits established for the target application. Often, the action listed as the appropriate response is very much in alignment with "common sense." An example of this would be the action "add water and reduce concentration," if the sample results indicate the alkalinity concentration is too high. However, the value of a control plan is found in guidance with more non-routine analysis, especially for parameters like corrosion inhibitor packages or chlorides. • What levels are too high, or too low? • What type of additive is needed to restore corrosion inhibitor? Castrol laboratory staff can prepare a control plan specific to each cleaner, relying on customer input for targets (Figure 17). Parameter Frequenc y UO M LSL LCL M UC L USL Corrective Actions pH ≤LCL - Determine cause; Verify result and check concentration; Add product if concentration by alkalinity is low. Add pH adjuster if needed. pH ≥UCL - Determine cause; assess imminent need to lower pH due to failure effects or allow to self correct; If action is required, add water. Alkalinity ≤LCL - Determine cause; Add concentrate. Alkalinity ≥UCL - Determine cause; If concentration reduction is required, check if system design/running depth permits dilution, recheck after operating depth increase. If no alternative, perform partial dump of fluid. FA2% ≤LCL - Determine cause; Add Synlube L4 additive. FA2% ≥UCL - Stop coolant concentrate and Synlube L4 additions. Evaluate if stopping adds will allow self-correction and monitor trend. If concentration reduction is required, add water. FA2% ≥USL - Perform partial dump of fluid, reuse fluid in another system or store where practical. Chlorides >UCL - Perform risk assessment to determine the effect on ferrous corrosion. If corrosion observed in testing, then partial dump is required to lower chloride level - do not reuse. % by wt. n/a n/a n/a 0 0 ppm n/a n/a n/a 20 25 ppm n/a 170 250 350 600 gpg n/a 10 15 20 35 PP M n/a n/a 8 3 100 250 350 Chloride Weekly 4 5 6 Weekly 8 % FA2% 8.8 9 9.6 6 3 4 5 Concentration (Alkalinity) Weekly 10 10 n/a Weekly % Weekly pH Hardness Dirt Dirt ≥UCL - Verify filtration unit is working properly. If not, report to maintenance team and evaluate index time and monitor effect . Dirt ≥USL - Place a centrifuge on the system to reduce dirt levels. If centrifuge does not reduce dirt level within control limits, investigate to determine the source of the dirt. Hardness ≥UCL - assess risk on machining performance, foam, corrosion, filtration, and residues - If any parameter out of control - follow corrective actions for specific parameter and Weekly Figure 17. Example of a Castrol control plan for a cleaner. Q35

Articles in this issue

Links on this page

view archives of Castrol GPS - GUIDE TO INDUSTRIAL PRODUCTS AND SERVICES