Technical Training and Reference Info Lubrication Technical Training 1 800 255 4417 www.castrol.com/GPS March 2017 Compressors Compressor Cleaning and Oil Conversion Compressor Cleaning Procedure with Detergent Cleaner (such as Castrol Techniclean SC 320) The following changeover procedure is recommended for compressors that contain a minimal to moderate level of buildup: 1. Operate the unit for at least one hour to get the system to normal operating temperature. 2. Sample the compressor oil to determine amount of contaminants. 3. Based on the results obtained from laboratory test report, charge the system with the recommended 3-5% by volume of Techniclean SC 320. 4. System should be run for a minimum of 36 to 72 hours before oil is drained and changed. Note: No advantages may be obtained by continuing use for more than 72 hours. 5. Drain oil and refill system with the appropriate compressor oil.* 6. Sample oil after 36 to 48 hours. This sample will serve as the baseline and will help determine the success level of the changeover. *Note: If significant volume of contaminated oil remains in the system after draining, a flushing step to eliminate the remaining amount is recommended. R85