Issue link: http://read.dmtmag.com/i/814629
Technical Training and Reference Info Lubrication Technical Training 1 800 255 4417 www.castrol.com/GPS March 2017 Hydraulics Figure 21. The beta ratio (efficiency) of two 3-micron filters can be quite different. Filtration and Contamination Control To achieve the desired particle count, contaminant ingress should be minimized and filtration of the proper size, efficiency and number must be installed on the hydraulic system. Figure 20 provides guidance on the filter size needed to attain a particular target, assuming the use of absolute filters with beta ratio of 200 or better (see beta ratio in next section). Figure 20. Filter size needed to achieve a given particle count target. Filter Classifications Filters are classified in the following two ways: • Nominal filtration — Arbitrary rating provided by the filter manufacturer — No standard followed; different for each manufacturer • Absolute filtration — Multi-pass ISO standard used to rate them — Rated with a micron size and efficiency (known as "beta ratio") Nominal filtration can be useful for some general lubrication applications requiring basic filtration, but hydraulic systems should always use absolute filtration so the exact performance is known. Absolute filtration is rated using a standard ISO multi-pass test, allowing micron size and efficiency to be comparable across manufacturers. Capture efficiency of a filter is provided as a beta ratio at a particular micron size. Beta ratio = # of particles upstream of the filter/ # of particles downstream of the filter In this example (Figures 21 and 22), 200 particles are sent to each of two 3-micron filters. • The top filter allows 100 particles downstream for a beta ratio of only 2; this would be considered a nominal filter. • The bottom filter only allows 1 particle downstream for a beta ratio of 200; this would be considered an absolute filter with efficiency suitable for hydraulics. This example highlights the need to know not only the micron size of a filter, but also its beta ratio. Figure 22. Beta ratio converted to efficiency. Efficiency % = [(beta -1) / beta] *100 Beta Ratio 1 2 5 10 20 75 100 200 1000 5000 Efficiency,% 0 50 80 90 95 98.7 99 99.5 99.9 99.98 A filter with beta ratio of at least 100 (99% efficiency) is recommended for use in hydraulic systems. Many of the top filter manufacturers now sell beta 1000 elements (99.9% efficiency) as standard. Target Filter Needed* 20/18/15 20 micron 19/17/14 10 micron 18/16/13 5 micron 17/15/12 3 micron 16/14/11 3 micron** 15/13/10 3 micron** *Assuming absolute filtration (beta>200). ** Two or more filters of this size may be needed to achieve target. R48