Technical Training and Reference Info Lubrication Technical Training 1 800 255 4417 www.castrol.com/GPS March 2017 Hydraulics Filtration and Contamination Control Filter Location Filters may be placed in several locations within the system. For example: • Suction strainers • Pressure line filters • Return line filters • Kidney loop filters Suction strainers are on the inlet of the pump and may be external to the reservoir; more commonly, they are submerged in the oil inside the reservoir. These are mesh-type strainers that are designed to keep large items out of the pump, but they do not provide removal of small micron particles. They should be inspected regularly to ensure they are not clogged or collapsed. Pressure line filters are located on the main line(s) going out from the pump. Often, they are used in systems that have critical components downstream to ensure that any particulate is removed prior to reaching these components. For systems with servo and proportional valves, a non-bypass pressure line filter is recommended to protect the valve at all times. Return line filters are the most common type used in hydraulics. They provide filtration on the low-pressure side of the system for all hydraulic fluid returning to the reservoir. Kidney loop filters are offline filter systems that are not part of the main hydraulic circuit. Their purpose is to filter the oil in the reservoir constantly; they may be permanently installed on the system or be portable, as in a filter cart (Figure 23). Permanent kidney loop systems are useful where a very low particle count is desired, such as in systems containing servo valves. Portable units are useful for occasional polishing of systems that show high particle counts during oil analysis. If particle counts on a particular system are regularly high, this indicates a need to reduce contaminant ingress and/or upgrade on-board filters to maintain the desired target. Kidney loop filters should always have the inlet and outlet at opposite ends of the reservoir to ensure all oil in the tank is filtered. Breathers Hydraulic systems have a tendency to "breathe" air in and out due to changes in the oil level in the tank, temperature fluctuations and atmospheric conditions. Breathers allow reservoir access to the open atmosphere for this purpose, and thus can be a major source of contaminant ingress. Many hydraulic systems come equipped with poor breathers that have little filtration and no water removal capabilities. But breathers with known filter rating (micron and beta ratio) and water removal should be used to eliminate this ingress point. An example of this type of breather is shown in Figure 24. This particular style uses a desiccant to remove water and a color change (blue to pink) to indicate when to change the breather. Many other high-quality breather types are available to suit the given environment, including high humidity, harsh temperatures, heavy duty and full reservoir isolators (bladder style) for extreme contaminant atmospheres. Figure 23. Portable kidney loop filter (a.k.a. "filter cart"). Figure 24. Disposable breather with 3-micron beta 200 filtration and desiccant for water removal. Courtesy of Des-Case Corporation. R49